Reyrolle relays
ARGUS 1
 | Single or three – phase three – stage overcurrent protection with DT
or IDMT characteristic |
 | Earth fault three-stage protection with DT or IDMT char. |
 | Sensitive or restricted earth fault protection |
 | Event recorder |
 | Disturbance recorder |
 | Breaker failure protection |
 | Trip circuit supervision |
ARGUS 2
 | Single or three – phase three – stage directional overcurrent
protection with DT or IDMT characteristic |
 | Directional earth fault (three stage) protection with DT or IDMT char. |
 | Sensitive or restricted earth fault protection |
 | Event recorder |
 | Disturbance recorder |
 | Breaker failure protection |
 | Trip circuit supervision |
ARGUS 3
 | Overcurrent protection |
 | Earth fault protection |
 | Autorecloser (multishot) |
ARGUS 4
 | Overcurrent protection |
 | Earth fault protection |
 | Autorecloser (multishot) |
ARGUS 5
Bi-directional version of Argus 3 with separate independent settings for
forward and reverse overcurrent protection
 | Overcurrent protection |
 | Earth fault protection |
 | Autorecloser (multishot) |
ARGUS 6
Bi-directional version of Argus 4 with separate independent settings for
forward and reverse overcurrent char.
 | Overcurrent protection |
 | Earth fault protection |
 | Autorecloser (multishot) |
 | Disturbance recorder (5 waveform records |
 | Event recorder (last 500 events) |
ARGUS 7 Synchronizing relay with undervoltage & differential
voltage
Solkor R / Rf Feeder differential relay
Functions to be tested:
 | Line differential protection |
 | |
Solkor-M Feeder differential relay
Type SK2 (101,102,103)
 | Line differential protection |
 | Communication signal monitoring |
 | Event recording |
 | Disturbance recording facilities |
 | Internal and external intertrip |
Solkor Microphase (FM) Feeder differential relay
Type MF1 (101,102,103) ; From 220 kV upwards
 | Line differential protection |
 | Communication signal monitoring |
 | Event recording |
 | Disturbance recording facilities |
 | Internal and external intertrip |
2DAB & 2DABT Breaker failure relay
 | Instantaneous overcurrent with DT char. |
Duobias-M Transformer overall differential protection
 | Current differential protection |
 | Differential high-set overcurrent protection |
 | Restricted earth fault protection |
 | Breaker failure protection |
Supertap Voltage regulating relay
 | Voltage regulating function |
 | Parallel operation based on a modified negative reactance principle |
 | Line drop compensation using a single control |
 | Effective runaway protection |
 | Fast tap down feature |
 | Coupling control |
 | Bandwidth control |
Motorprot RHo Motor protection relay
 | Thermal overload protection |
 | Undercurrent protection |
 | Under/Overvoltage detection |
 | Under/Overfrequency detection |
 | Phase unbalance protection |
 | Phase rotation detection |
 | Earth fault protection |
 | Short circuit protection |
 | Power high/low monitoring |
 | Stall and locked rotor protection |
 | Acceleration time monitoring |
DAD Busbar protection (High impedance circulating current
relay)
 | Current differential protection |
 | Harmonic rejection |
 | Open circuit current transformer supervision |
Gamma 1 Generator protection
For medium and large generators, low or high impedance earthed
 | Voltage controlled or restrained overcurrent protection |
 | Neutral voltage displacement (95% stator earth fault) protection |
 | Neutral overcurrent protection |
 | Two step overvoltage and two step under voltage protection |
 | Four step over and under frequency protection |
 | Reverse or low forward power protection |
 | VT supervision |
 | Rate of change of frequency protection |
 | Biased generator phase differential protection |
 | Earth differential protection (for low impedance earthed) |
 | Negative phase sequence overcurrent protection |
 | Loss of field protection |
 | Overexcitation (V/Hz) protection |
 | Inadvertent generator energizing |
 | Generator circuit breaker fail protection |
Gamma 2 Generator protection
For large generators
 | Voltage controlled or restrained overcurrent protection |
 | Neutral overcurrent protection |
 | Two step overvoltage and two step under voltage protection |
 | Four step over and under frequency protection |
 | Reverse or low forward power protection |
 | VT supervision |
 | Rate of change of frequency protection |
 | Biased generator phase differential protection |
 | Earth differential protection (for low impedance earthed) |
 | Negative phase sequence overcurrent protection |
 | Loss of field protection |
 | Overexcitation (V/Hz) protection |
 | Inadvertent generator energizing |
 | Generator circuit breaker fail protection |
 | Two zones distance backup protection |
 | 100 stator earth fault protection |
Ohmega Digital distance protection
Two types:300 and 400
 | Shaped MHO characteristics |
 | Quadrilateral EF characteristics |
 | Communication scheme logic |
 | Directional earth fault protection |
 | Single shot auto-recloser |
 | Check synchronizing |
 | Over & under voltage protection |
 | Overcurrent protection |
 | High set overcurrent protection |
 | Circuit breaker fail protection |
 | Under over frequency protection |
 | Sensitive earth fault protection |
 | Switch on to fault protection |
 | Mutual compensation for parallel lines |
 | Voltage memory |
 | Power swing blocking or tripping |
 | Thermal overload protection |
 | Current reversal logic |
 | Open conductor detection |
 | Voltage transformer supervision |
 | Fault locator |
 | Event recording |
 | Fault recording |
BT1 Arc monitoring and protection
Models avilable:101, 103, 105, 108
 | Digital overcurrent protection |
 | Circuit breaker failure protection with DT char. |
 | Arc protection |