Reyrolle relays

ARGUS 1

Single or three – phase three – stage overcurrent protection with DT or IDMT characteristic
Earth fault three-stage protection with DT or IDMT char.
Sensitive or restricted earth fault protection
Event recorder
Disturbance recorder
Breaker failure protection
Trip circuit supervision

ARGUS 2

Single or three – phase three – stage directional overcurrent protection with DT or IDMT characteristic
Directional earth fault (three stage) protection with DT or IDMT char.
Sensitive or restricted earth fault protection
Event recorder
Disturbance recorder
Breaker failure protection
Trip circuit supervision

 

ARGUS 3

Overcurrent protection
Earth fault protection
Autorecloser (multishot)

ARGUS 4

Overcurrent protection
Earth fault protection
Autorecloser (multishot)

ARGUS 5

Bi-directional version of Argus 3 with separate independent settings for forward and reverse overcurrent protection

Overcurrent protection
Earth fault protection
Autorecloser (multishot)

ARGUS 6

Bi-directional version of Argus 4 with separate independent settings for forward and reverse overcurrent char.

Overcurrent protection
Earth fault protection
Autorecloser (multishot)
Disturbance recorder (5 waveform records
Event recorder (last 500 events)

ARGUS 7 Synchronizing relay with undervoltage & differential voltage

 

 

Solkor R / Rf Feeder differential relay

Functions to be tested:

Line differential protection
 

Solkor-M Feeder differential relay

Type SK2 (101,102,103)

Line differential protection
Communication signal monitoring
Event recording
Disturbance recording facilities
Internal and external intertrip

 

Solkor Microphase (FM) Feeder differential relay

Type MF1 (101,102,103) ; From 220 kV upwards

Line differential protection
Communication signal monitoring
Event recording
Disturbance recording facilities
Internal and external intertrip

 

2DAB & 2DABT Breaker failure relay

Instantaneous overcurrent with DT char.

 

Duobias-M Transformer overall differential protection

Current differential protection
Differential high-set overcurrent protection
Restricted earth fault protection
Breaker failure protection

 

Supertap Voltage regulating relay

Voltage regulating function
Parallel operation based on a modified negative reactance principle
Line drop compensation using a single control
Effective runaway protection
Fast tap down feature
Coupling control
Bandwidth control

 

 

Motorprot RHo Motor protection relay

Thermal overload protection
Undercurrent protection
Under/Overvoltage detection
Under/Overfrequency detection
Phase unbalance protection
Phase rotation detection
Earth fault protection
Short circuit protection
Power high/low monitoring
Stall and locked rotor protection
Acceleration time monitoring

DAD Busbar protection   (High impedance circulating current relay)

Current differential protection
Harmonic rejection
Open circuit current transformer supervision

 

Gamma 1 Generator protection

For medium and large generators, low or high impedance earthed

Voltage controlled or restrained overcurrent protection
Neutral voltage displacement (95% stator earth fault) protection
Neutral overcurrent protection
Two step overvoltage and two step under voltage protection
Four step over and under frequency protection
Reverse or low forward power protection
VT supervision
Rate of change of frequency protection
Biased generator phase differential protection
Earth differential protection (for low impedance earthed)
Negative phase sequence overcurrent protection
Loss of field protection
Overexcitation (V/Hz) protection
Inadvertent generator energizing
Generator circuit breaker fail protection

 

Gamma 2 Generator protection

For large generators

Voltage controlled or restrained overcurrent protection
Neutral overcurrent protection
Two step overvoltage and two step under voltage protection
Four step over and under frequency protection
Reverse or low forward power protection
VT supervision
Rate of change of frequency protection
Biased generator phase differential protection
Earth differential protection (for low impedance earthed)
Negative phase sequence overcurrent protection
Loss of field protection
Overexcitation (V/Hz) protection
Inadvertent generator energizing
Generator circuit breaker fail protection
Two zones distance backup protection
100 stator earth fault protection

 

Ohmega Digital distance protection

Two types:300 and 400

Shaped MHO characteristics
Quadrilateral EF characteristics
Communication scheme logic
Directional earth fault protection
Single shot auto-recloser
Check synchronizing
Over & under voltage protection
Overcurrent protection
High set overcurrent protection
Circuit breaker fail protection
Under over frequency protection
Sensitive earth fault protection
Switch on to fault protection
Mutual compensation for parallel lines
Voltage memory
Power swing blocking or tripping
Thermal overload protection
Current reversal logic
Open conductor detection
Voltage transformer supervision
Fault locator
Event recording
Fault recording

 

BT1 Arc monitoring and protection

Models avilable:101, 103, 105, 108

Digital overcurrent protection
Circuit breaker failure protection with DT char.
Arc protection
 